# Heat pumps for Randolph's post-war houses

> Ducted heat pumps for Randolph capes, raised ranches and split-levels on oil, gas or baseboard, with Mass Save rebates and what the new stretch code changes.

URL: https://clementbostonheatpumps.com/service-areas/randolph/

Service area, Massachusetts

Ducted heat pumps for Randolph capes, raised ranches and split-levels on oil, gas or baseboard, with Mass Save rebates and what the new stretch code changes.

(857) 837-1475

Last Updated: November 12, 2026

Electric

National Grid

Rebates

Mass Save

Permits

Town of Randolph building department

Energy code

Stretch energy code effective January 1, 2026

## Inside a North Randolph oil-to-heat-pump conversion

Insulated trunk and branches on the attic platform above the upper level

Drywall soffit carrying the lower-level trunk along the family room wall

### Two levels, no ducts

A 1968 raised ranch in North Randolph heats with an oil boiler and baseboard on two zones. The boiler leaks at the coil, and the window units are tired. There are no ducts on either level, the lower level has finished drywall ceilings, and the owners want central cooling upstairs.

### One system per level

The attic over the upper level gets a 2-ton air handler with six short ceiling runs, the easiest route in a raised ranch. The utility room gets a 1.5-ton unit feeding the family room and office through a 22-foot drywall soffit. No closet stacks between levels, so two systems beat one.

### The panel and the tank

A load calculation on the 100-amp panel shows room for two heat pump circuits alongside the range and dryer, so the service stays. The 275-gallon tank is pumped out and removed through the lower-level door under a fire department permit, once the heat pumps carry the house.

### Code and rebate

Randolph's stretch code doesn't change a replacement like this; ducts are mastic-sealed and lines insulated. National Grid sponsors Mass Save's whole-home rebate for replacing oil, which needs the boiler gone. Each system is pressure-tested, evacuated below 500 microns and charged by weight for its line length.

*Project facts*

| Service | Oil-to-heat-pump conversion with new ducts |
| --- | --- |
| Where | North Randolph |
| House | 1968 raised ranch, about 1,900 sq ft |
| Before | Oil boiler, baseboard, window AC |
| After | 2-ton attic and 1.5-ton lower-level heat pumps |
| Price | $31,600 before rebates, tank removal included |
| Time on site | Seven working days |

## What brings people to us in Randolph

### A raised ranch on oil hot water

Baseboard loops on two levels and no ducts. An attic air handler serves the upper floor and a small unit in the lower level handles the rest.

### A split-level with a tired furnace

The ducts are already there. We measure them, enlarge the return if it needs it, and the heat pump takes over.

### A condo on electric baseboard

Nearly one Randolph home in five heats with electricity. A ducted heat pump delivers two to three times the heat per kilowatt-hour.

### An addition or gut renovation

The stretch code now applies to new homes and major renovations, so the heating plan goes into the permit drawings.

Before you replace a Randolph oil boiler or furnace, two questions decide the plan: does the house have ducts, and is the work part of a renovation? [Clement Boston Heat Pumps](https://clementbostonheatpumps.com/) handles heat pump installation in Randolph, MA, and we answer both on the first visit.

The second question matters more than it used to, because Randolph’s stretch energy code took effect on January 1, 2026. Most of the town is post-war capes, ranches and split-levels, and about one home in five still burns oil.

## What the new stretch code means for you

For a heating replacement in an existing house, almost nothing. The stretch code raises the bar for new homes and major renovations, so it matters if you’re adding a wing or gutting a floor.

### Replacing the heat in a house you live in

Swapping a furnace, boiler or baseboard for a heat pump stays a mechanical job. The code shows up in sealed duct joints, insulated refrigerant lines and the permit inspections, not in which equipment you can choose.

### Building an addition or gutting a floor

New construction and major renovations now carry a performance target, usually proven with a HERS rating. A cold-climate heat pump helps meet it. If you’re planning an addition, we size the heat with the whole house in mind; our [whole-home heat pump page](https://clementbostonheatpumps.com/whole-home-heat-pump/) explains why one right-sized system beats a second small one.

## Which company pays your rebate

It depends on what you burn now. National Grid sells Randolph its electricity and Eversource sells its gas, and each sponsors a different side of Mass Save.

- **Oil, propane or electric baseboard:** National Grid, as the electric sponsor, handles the whole-home rebate.
- **Natural gas:** Eversource, as the gas sponsor, handles it once the gas heat is taken out.
- **Same rules on both sides:** ENERGY STAR cold-climate listed equipment, a contractor in Mass Save’s Heat Pump Installer Network, the old system removed or disconnected, and proof of weatherization.

Whole-home pays $2,650 a ton with an $8,500 cap; installs from January 1, 2027 get $2,350 a ton, capped at $7,500. The [rebate guide](https://clementbostonheatpumps.com/guide/mass-save-heat-pump-rebates/) covers income-eligible amounts and the sizing bonus.

## Capes, raised ranches and split-levels

Only about 14% of Randolph homes predate 1940. Most are detached houses built after the war, and their layout decides where the air handlers go more than their age does.

### Raised ranches on hot-water baseboard

A raised ranch with an oil boiler has two levels and no ducts. The upper floor gets an [attic air handler](https://clementbostonheatpumps.com/attic-air-handler-heat-pump/) with ceiling registers, which is the shortest route in this house type. The lower level gets a small air handler in the utility room, and the two share one outdoor unit or get one each, depending on the load.

### Split-levels and ranches with a furnace

Here the supply and return runs are already in place. Heat pumps push a larger volume of gentler air than a furnace, so the static pressure reading and the return’s free area tell us whether the existing runs can carry it. One undersized return is the common fix. See [furnace to heat pump conversion](https://clementbostonheatpumps.com/furnace-to-heat-pump-conversion/).

### Capes

A cape’s bedrooms sit under the roof, behind kneewalls. The kneewall space can hold an air handler and short duct runs, which keeps the second floor even without opening ceilings below.

### The electrical panel

Plenty of post-war houses still run on a 100-amp service. A heat pump adds a large circuit, and an electric range or dryer may already be using the headroom. We do a load check on the panel first. If the service has to grow, our typical range for an [electrical service upgrade](https://clementbostonheatpumps.com/electrical-panel-upgrade-for-heat-pump/) is $3,000 to $6,500, coordinated with National Grid.

### Condos and apartments

Nearly a fifth of Randolph’s homes are in complexes of five units or larger, where baseboard heat is common. A compact ducted unit tucked in a closet takes over from the baseboard, and the condo board signs off on the outdoor unit’s spot. See [baseboard heat to heat pump](https://clementbostonheatpumps.com/baseboard-heat-to-heat-pump/).

## Oil, baseboard and gas: what you save

Oil and electric baseboard cost the most per delivered BTU. A cold-climate heat pump, billed on National Grid’s heat pump rate, undercuts both on running cost; only against gas is the comparison close.

National Grid’s heat pump rate trims the distribution part of every winter kilowatt-hour on your bill, November through April. Transmission stays at the standard price; the [winter rate guide](https://clementbostonheatpumps.com/guide/heat-pump-electric-rate-massachusetts/) shows how it works.

### The oil tank comes out too

Once the boiler is gone, the tank has no job. Our typical range to take out a reachable basement tank is $600 to $1,500, and the local fire department issues the removal permit. The [heat pump vs oil guide](https://clementbostonheatpumps.com/guide/heat-pump-vs-oil-heat/) lays the two fuels side by side.

## Paperwork, rebates and code in Randolph

The building department in Randolph handles the wiring permit and the ductwork permit. We confirm how it takes filings, and what it charges, for your address first.

| What | The Randolph figure |
| --- | --- |
| Electric company | National Grid |
| Gas company | Eversource |
| Energy code | Stretch code effective January 1, 2026; specialized code not adopted |
| Heating fuel | Gas 55%, oil 21%, electricity 19%, propane 4% |
| Detached houses | About 63% |
| Outdoor unit rules | Confirmed per address |

## How the work runs on a Randolph job

It starts at the house. We calculate the heat loss room by room, trace the ducts or plan new routes, open the electrical panel and pick the outdoor pad’s spot with you.

1. **Estimate in writing,** listing what the outdoor unit delivers at 5°F, any new or changed ducts, the electrical work, the tank, the permits, which sponsor pays the rebate, and the total.
2. **Permits from the building department and the fire department.** Work on existing ducts takes three to five days on site; a raised ranch needing new runs takes about seven.
3. **The boiler or furnace is disconnected,** because Mass Save’s whole-home tier doesn’t pay while the old system can still run.
4. **Startup checks:** a nitrogen hold test on the line set, evacuation to under 500 microns, refrigerant weighed in for the measured line length, airflow and static measured, and the strip-heat lockout temperature written down.

Our [sizing guide](https://clementbostonheatpumps.com/guide/heat-pump-sizing/) explains the load calculation. [Holbrook](https://clementbostonheatpumps.com/service-areas/holbrook/) next door shares both utilities but stays on the base code, while [Braintree](https://clementbostonheatpumps.com/service-areas/braintree/) has its own light plant.

## Services in Randolph

- [Service**Oil to heat pump conversion** Retire the oil furnace or hydro-air boiler, cap the oil line and heat and cool through the ducts you have.](https://clementbostonheatpumps.com/oil-to-heat-pump-conversion/)
- [Service**Furnace to heat pump conversion** Take out the gas or propane furnace and heat and cool through the same ducts with a heat pump.](https://clementbostonheatpumps.com/furnace-to-heat-pump-conversion/)
- [Service**Baseboard heat to heat pump** Replace electric baseboard with a ducted heat pump that heats on far less electricity and cools too.](https://clementbostonheatpumps.com/baseboard-heat-to-heat-pump/)
- [Service**Attic air handlers** An attic air handler that heats and cools the upper floor, with short sealed ducts and a guarded drain.](https://clementbostonheatpumps.com/attic-air-handler-heat-pump/)
- [Service**Oil tank removal** The old basement tank pumped, cleaned, removed and permitted once the heat pump is running.](https://clementbostonheatpumps.com/oil-tank-removal/)
- [Service**Panel and service upgrades** A service load calculation first, and a 200-amp upgrade only when the heat pump and the house need it.](https://clementbostonheatpumps.com/electrical-panel-upgrade-for-heat-pump/)

## How a job usually runs in Randolph

### First call

You tell us what heats and cools the house now, which rooms aren't working, and roughly where the house is.

### Home visit

We measure the house for a load calculation, test the ducts, check the panel and look for an outdoor spot.

### Written estimate

Equipment, duct changes, electrical, permits and the rebate path, line by line, with our price.

### Install

Permits first, then the work: usually two to five working days on site.

### Commissioning

Pressure test, vacuum, charge by weight, airflow and controls set before we call it done.

## Neighborhoods, landmarks and routes

- Randolph Center
- North Randolph
- West Corners
- Tower Hill
- Great Pond area

### Landmarks

- Great Pond
- Blue Hills Reservation
- Turner Free Library
- Stetson Hall
- Randolph Town Hall

### Getting around

- Route 24
- Route 28 (Main Street)
- Route 139
- I-93 at the Route 24 interchange
- Middleborough/Lakeville Line at Holbrook/Randolph station

[Open Randolph, MA in Google Maps](https://www.google.com/maps/search/?api=1&query=Randolph%2C%20MA)

## Randolph: questions

### What changed when Randolph adopted the stretch energy code?

The stretch code took effect in Randolph on January 1, 2026. It sets tougher energy targets for new homes and major renovations, usually shown through a HERS rating. It doesn't change a straight heating replacement in an existing house, and Randolph has not adopted the specialized code.

### How much is a heat pump for a Randolph raised ranch on oil?

With no ducts, our typical range for a heat pump with new ductwork is $20,000 to $40,000 and up before rebates; a house with reusable ducts is $15,000 to $28,000 and up. National Grid sponsors Mass Save's whole-home rebate for replacing oil. Your written estimate sets the price.

### Which company handles my Mass Save rebate in Randolph if I heat with gas?

Randolph's gas company is Eversource, which sponsors Mass Save on the gas side, while National Grid sponsors the electric side. Replacing gas heat qualifies through Eversource; replacing oil, propane or baseboard qualifies through National Grid. The equipment and paperwork rules are the same.

### Do I need a permit to remove an oil tank in Randolph?

Yes. Removing a heating oil tank needs a permit from the local fire department, and the fee is confirmed with the permit. Our typical range for an accessible basement tank is $600 to $1,500.

### Are there Randolph rules about where a heat pump outdoor unit can go?

Local setback and noise rules are confirmed per address before we choose a spot. We keep the unit level on a stand, clear of the drip line and snow from the roof, and away from bedroom windows on the neighbor's side.

## Nearby service areas

- [Service area**Holbrook** Ducted heat pumps for Holbrook capes and ranches heated by oil, with the oil tank removed, Mass Save rebates through National Grid and a base-code permit path.](https://clementbostonheatpumps.com/service-areas/holbrook/)
- [Service area**Braintree** Ducted heat pumps for Braintree homes on BELD power, planned around BELD's gas and non-gas rebate tiers, its 12-inch stand rule and Mass Save for gas homes.](https://clementbostonheatpumps.com/service-areas/braintree/)
- [Service area**Canton** Ducted heat pumps for Canton homes and condos on Eversource, planned around the specialized energy code that takes effect in town on January 1, 2027.](https://clementbostonheatpumps.com/service-areas/canton/)

## Guides for houses in Randolph

- [Decision Guide**Is a heat pump better than oil heat in Massachusetts?** Running cost worked out from Massachusetts fuel prices and winter heat pump rates, plus the comfort, cooling, tank and hot water questions that come with the switch.](https://clementbostonheatpumps.com/guide/heat-pump-vs-oil-heat/)
- [Learn**How do Mass Save heat pump rebates work?** The three rebate tiers, the conditions behind each, the dates that change them, and what happens in towns with their own light plant.](https://clementbostonheatpumps.com/guide/mass-save-heat-pump-rebates/)
- [Learn**How does the heat pump electric rate work in Massachusetts?** Which part of your electric bill the seasonal rate lowers, why it applies to the whole house, how enrollment works, and what it means for the switch from oil or gas.](https://clementbostonheatpumps.com/guide/heat-pump-electric-rate-massachusetts/)
- [Learn**What size heat pump do I need?** Why square footage and the old unit's tonnage both mislead, what a room-by-room load calculation measures, and how the result turns into equipment.](https://clementbostonheatpumps.com/guide/heat-pump-sizing/)
- [Cost Guide**How much does heat pump installation cost in Massachusetts?** Our typical ranges for Boston-area ducted heat pump jobs, what's inside the price, and what rebates do to it.](https://clementbostonheatpumps.com/guide/heat-pump-installation-cost-massachusetts/)

## Get an estimate in Randolph

Tell us what heats the house now and which rooms aren't working in Randolph.

(857) 837-1475