# Convert baseboard heat to a heat pump in Boston, MA

> Electric baseboard turns each kilowatt-hour into one unit of heat. A ducted heat pump on new ducts uses far less and cools too. Our range: $20,000 to $40,000+.

URL: https://clementbostonheatpumps.com/baseboard-heat-to-heat-pump/

Service

Replace electric baseboard with a ducted heat pump that heats on far less electricity and cools too.

(857) 837-1475

Last Updated: November 12, 2026

Sized

From a room-by-room load calculation at your town's design temperature

Measured

Duct static pressure and airflow before and after

Tested

Nitrogen pressure test and deep vacuum before the charge

In writing

Equipment, duct work, electrical and permits listed line by line

## A typical Lexington baseboard-to-heat-pump conversion

Electric baseboard under a living room window

New basement trunk and branches feeding the floor registers

### Eleven heaters, no ducts

A 1962 ranch in Lexington, about 1,600 square feet on one floor over an unfinished basement. Eleven electric baseboards on eight 240-volt circuits heat it, three window units cool it, and January brings the biggest electric bill of the year. Before sizing, the attic gets air sealed and insulated through a Mass Save home energy assessment.

### Sizing for Hanscom nights

Lexington runs colder than Logan, so the load is run at 5°F: 27,600 BTU an hour after the attic work. A 3-ton cold-climate unit rated for 30,000 BTU an hour at 5°F covers it. A wall unit in each of six rooms is the other route; the owners choose registers and nothing mounted on the walls.

### Ducts from the basement

The air handler sits near the laundry. A sealed trunk runs along the center beam, with nine branches to floor registers set near the exterior walls where the baseboards worked, and two floor returns, one in the hall and one in the living room. Every room gets supply, both baths included.

### Baseboards out, panel freed

The baseboards heat until commissioning, then all eleven come off the walls, their circuits are disconnected and the boxes blanked. That frees eight double-pole breakers, so the 200-amp panel takes the heat pump's two circuits with room to spare. The outdoor unit stands 24 inches up in the back yard, and backup heat locks out above 10°F.

*Project facts*

| Service | Baseboard heat to ducted heat pump |
| --- | --- |
| Where | Lexington |
| House | 1962 single-story ranch, about 1,600 sq ft |
| Before | 11 electric baseboards on 8 circuits, window AC |
| After | 3-ton cold-climate heat pump on new basement ducts |
| Price | $24,700 before rebates |
| Time on site | Six working days |

Your January electric bill is the biggest of the year, every room has its own dial, and summer means window units. [Clement Boston Heat Pumps](https://clementbostonheatpumps.com/) helps owners convert baseboard heat to heat pump heating and cooling with a ducted system: new ducts, one cold-climate heat pump, and the baseboards gone.

The ducts are new, so our typical range is $20,000 to $40,000 and up before rebates. In return the house uses far less electricity for the same heat, and you get central air.

## What the first visit looks at in a baseboard house

Three things decide this job: where ducts can run, how much heat each room loses, and what the panel holds. We measure all three on the first visit and put them in the written estimate.

### Room by room

Baseboard houses are often heated unevenly, because each room’s dial was set by whoever was in it. The heat loss calculation looks at each room’s walls, windows and air leaks, which sets the register size for that room instead of copying the old heater’s wattage.

### The layout

We look at the basement, crawl space or attic for a trunk route, find a spot for the air handler near the middle of the house, and pick a return location that reaches every bedroom with the doors closed.

## Heat pump vs electric resistance, in plain numbers

A baseboard heater turns each kilowatt-hour into one kilowatt-hour of heat. A heat pump spends its kilowatt-hour moving heat in from outdoors, delivering two to three or more units of heat for each unit of electricity through most of a Boston winter.

That ratio is the coefficient of performance, or COP. Baseboard is always 1. A cold-climate heat pump’s COP falls as the outdoor air gets colder, but stays above 1 down to the coldest temperatures its rating covers. At a seasonal COP of 2.5, the same heat takes about 40% of the electricity.

### The part that’s still resistance

The air handler’s backup strips are resistance heat, COP 1, the same as your baseboards. They help during defrost and on the hardest nights. We set a lockout so they stay off above a chosen outdoor temperature; [heat pump aux heat](https://clementbostonheatpumps.com/guide/heat-pump-aux-heat/) explains why that setting matters.

### The electric rate changes too

Heating with a heat pump makes an Eversource or National Grid customer eligible for the [seasonal heat pump rate](https://clementbostonheatpumps.com/guide/heat-pump-electric-rate-massachusetts/), which lowers distribution charges on all household electricity from November through April. Baseboard heat alone doesn’t qualify.

## Where the ducts go in a house built without them

The duct design is the real job here. Ranches and capes with a basement take ducts from below; slab houses and upper floors take them from the attic. We draw the layout before pricing, because it sets most of the cost.

- **Ranch with a basement.** A trunk along the center beam, floor registers near the exterior walls, and returns in the hall and the main living space.
- **Ranch on a slab.** An attic air handler and ceiling registers, with the ducts sealed and insulated to R-8 against attic cold.
- **Cape or two-story.** The basement feeds the first floor; the second floor is fed from the attic or kneewall spaces.

Registers go where the baseboards did their work, near windows and exterior walls, so the coldest surfaces get warm air. The [ductwork page](https://clementbostonheatpumps.com/heat-pump-ductwork/) covers sizing and sealing, and an [attic air handler](https://clementbostonheatpumps.com/attic-air-handler-heat-pump/) covers the overhead route.

## What your electric panel looks like afterward

Usually better than before. A house heated by baseboard has a row of 240-volt heating breakers, and removing them frees space and capacity for the heat pump’s two circuits.

We count every heating circuit, then run an electrical load calculation with the heat pump, its strips and anything you plan to add, like an EV charger. A house wired for electric heat was built for a big load, so the service may already be large enough. If not, our typical range for a [service upgrade](https://clementbostonheatpumps.com/electrical-panel-upgrade-for-heat-pump/) is $3,000 to $6,500.

### Taking the baseboards off

Each heater comes off the wall, its circuit is disconnected at the panel, and the junction box behind it gets a blank cover. The paint behind a heater is often unfinished or marked, so plan on touch-up along those walls.

## Sizing for the colder towns

Inland towns run colder. Hanscom Field in Bedford averages about five nights a year at or below 0°F, against fewer than one at Logan, so in towns like [Lexington](https://clementbostonheatpumps.com/service-areas/lexington/), [Burlington](https://clementbostonheatpumps.com/service-areas/burlington/) and [Woburn](https://clementbostonheatpumps.com/service-areas/woburn/) we check a unit’s output at 5°F with extra care.

Baseboard houses never had ducts, so nobody sealed their attics for a duct system either. A 1960s house may still have its original attic insulation. Air sealing and insulation lower the load before we pick equipment, and Mass Save’s whole-home rebate asks for proof of weatherization. Our [sizing guide](https://clementbostonheatpumps.com/guide/heat-pump-sizing/) and [cold-weather guide](https://clementbostonheatpumps.com/guide/do-heat-pumps-work-in-massachusetts/) go deeper.

## Rebates for leaving electric resistance

Electric resistance is one of the heating types Mass Save’s whole-home rebate covers when Eversource or National Grid supplies your electricity. The baseboards have to be removed or disconnected, and the heat pump has to carry the house.

In light plant towns, the town utility’s program applies instead: [Belmont](https://clementbostonheatpumps.com/service-areas/belmont/), [Reading](https://clementbostonheatpumps.com/service-areas/reading/), [Braintree](https://clementbostonheatpumps.com/service-areas/braintree/) and others set their own amounts. Per-ton Mass Save rates drop on January 1, 2027. The [rebate guide](https://clementbostonheatpumps.com/guide/mass-save-heat-pump-rebates/) covers both routes and the weatherization condition.

## Why ducted rather than a unit in every room

Wall-mounted ductless heads are a common fix for baseboard homes. We install only ducted systems, so here is the honest trade: ducted costs more up front because of the ducts, and gives you one quiet system behind registers.

Halls, baths and closets get conditioned air, filtration happens in one place, and no room carries an indoor unit on the wall. Our [ducted vs ductless guide](https://clementbostonheatpumps.com/guide/ducted-vs-ductless-heat-pump/) lays out both sides.

## How the job runs while you live there

A single-floor conversion on new basement ducts typically takes five to seven working days on site. The baseboards keep heating until the heat pump is commissioned, then come out, so the house is never without heat.

Duct work goes first, with registers cut into the floors room by room. The outdoor unit, line set and circuits follow, then commissioning: nitrogen pressure test, vacuum below 500 microns, charge by weight and measured airflow. The baseboards leave on the last day.

## What's included

- A panel survey that counts every baseboard circuit and what removing it frees up
- A load calculation and a duct layout for the floors you heat
- A written estimate listing ducts, equipment, electrical changes and the rebate path
- New supply and return ducts, with registers near the exterior walls the baseboards used to warm
- Baseboards disconnected and removed, their breakers cleared and the wall boxes covered
- Air handler with backup heat, and the backup lockout set and recorded
- Outdoor unit on a stand, line set and circuits
- Commissioning, then a walk-through of one thermostat in place of a dial in every room

## Electric baseboard, a ducted heat pump, and the wall-unit route

|  | Electric baseboard | Ducted heat pump | Wall-mounted ductless (we do not install) |
| --- | --- | --- | --- |
| Electricity per unit of heat | One unit of electricity for each unit of heat | About 40% as much at a seasonal efficiency of 2.5 | Similar to ducted |
| Cooling | None; window units | Central, in every room on the ducts | Rooms with an indoor unit |
| What you see in rooms | Heaters along the exterior walls | Registers, and one thermostat per system | An indoor unit high on the wall of each room |
| New ducts | No | Yes | No |
| Seasonal heat pump electric rate | Not eligible | Eligible with Eversource or National Grid | Eligible with Eversource or National Grid |

## Related resources

- [Decision Guide**Should I get a ducted or ductless heat pump?** Both are heat pumps. The difference is how the heat reaches each room, and that comes down to the ducts you have or could add.](https://clementbostonheatpumps.com/guide/ducted-vs-ductless-heat-pump/)
- [Learn**Why does my heat pump's aux heat keep coming on?** Backup heat is part of every cold-climate system. Here's when it should run, when it shouldn't, and the settings that decide which.](https://clementbostonheatpumps.com/guide/heat-pump-aux-heat/)
- [Learn**How does the heat pump electric rate work in Massachusetts?** Which part of your electric bill the seasonal rate lowers, why it applies to the whole house, how enrollment works, and what it means for the switch from oil or gas.](https://clementbostonheatpumps.com/guide/heat-pump-electric-rate-massachusetts/)
- [Learn**Do heat pumps work in Massachusetts?** What a Boston-area winter asks of a heat pump, how cold-climate equipment is rated, and what changes inland, in snow and on the coldest nights.](https://clementbostonheatpumps.com/guide/do-heat-pumps-work-in-massachusetts/)
- [Learn**What size heat pump do I need?** Why square footage and the old unit's tonnage both mislead, what a room-by-room load calculation measures, and how the result turns into equipment.](https://clementbostonheatpumps.com/guide/heat-pump-sizing/)

## How a job runs

### First call

You tell us what heats and cools the house now, which rooms aren't working, and roughly where the house is.

### Home visit

We measure the house for a load calculation, test the ducts, check the panel and look for an outdoor spot.

### Written estimate

Equipment, duct changes, electrical, permits and the rebate path, line by line, with our price.

### Install

Permits first, then the work: usually two to five working days on site.

### Commissioning

Pressure test, vacuum, charge by weight, airflow and controls set before we call it done.

## Baseboard heat to heat pump: questions

### How much less electricity does a heat pump use than baseboard heat?

Baseboard turns one kilowatt-hour into one kilowatt-hour of heat. A cold-climate heat pump delivers two to three or more through most of the winter, less on the coldest nights. At a seasonal average of 2.5, the same heat takes about 40% of the electricity. Your house sets the real number.

### Can I keep a couple of baseboards as backup?

The air handler already carries backup strips. Mass Save's whole-home rebate asks for the old system removed or disconnected, so baseboards left connected can put it at risk. We settle which, if any, stay before the estimate is written.

### Will taking out the baseboards free up my panel?

Often. Every baseboard circuit is a 240-volt breaker, and a house heated by them has many. Removing them frees space and capacity, which can be enough for the heat pump without a service upgrade. An electrical load calculation confirms it.

### My ranch sits on a slab. Can it still get ducts?

Yes, from above. The air handler sits in the attic or a closet and feeds ceiling registers. Attic ducts live in the cold, so they get sealed with mastic and insulated, and the attic floor gets its own air sealing first.

### Why not put a mini split in each room instead?

Wall-mounted ductless units are a common answer for baseboard houses, and we don't install them. Ducted means one system behind registers, air reaching halls and baths too, and nothing mounted on the bedroom walls. Our ducted vs ductless guide compares both fairly.

## Related services

- [Service**Heat pump ductwork** Duct testing, sealing, new returns and resized runs so a heat pump gets the air it needs.](https://clementbostonheatpumps.com/heat-pump-ductwork/)
- [Service**Panel and service upgrades** A service load calculation first, and a 200-amp upgrade only when the heat pump and the house need it.](https://clementbostonheatpumps.com/electrical-panel-upgrade-for-heat-pump/)
- [Service**Attic air handlers** An attic air handler that heats and cools the upper floor, with short sealed ducts and a guarded drain.](https://clementbostonheatpumps.com/attic-air-handler-heat-pump/)

## Get an estimate for baseboard heat to heat pump

Tell us what heats it now and which rooms aren't working. We'll measure, lay out the system and the ducts, and put the plan and the price in writing.

(857) 837-1475